Break-out Cables

Pigtail cables  |  Simplex cables  |  Duplex cables
 
Construction
1 Fibres Single mode 9/125 µm, multimode 50/125 µm, multimode 62.5/125 µm
2 Centre support member Glass fibre reinforced polymer (FRP)
3 Sub-units Semi-tight buffered simplex cables
4 Outer sheath LSZH
Temperature Range Transport and storage Installation In use
-30 °C to +60 °C -5 °C to +50 °C -20 °C to +60 °C
 
Mechanical Properties
Diameter of simplex cable sub-unit Fibre count Outer diameter Mass Minimum bend radius Max. tensile load Crush resistance
static dynamic
mm - mm kg/km mm mm N N/10cm
2 4 8.6 70 130 170 800 800
  6 8.6 70 130 170 1000 800
  8 10.1 95 150 200 1300 800
  12 12.6 145 190 250 1700 800
  16 12.4 130 190 250 750 800
  24 15.0 195 225 300 1400 800
2.4 4 10.3 100 150 200 1200 1000
  6 10.3 105 150 200 1500 1000
  8 11.9 135 180 240 1700 1000
  12 15.1 205 225 300 2700 1000
  16 14.6 185 225 300 1000 1000
  24 17.8 280 270 360 2000 1000
2.8 4 11.5 125 170 230 1300 1000
  6 11.5 130 170 230 1600 1000
  8 13.4 170 200 270 2000 1000
  12 17.0 260 250 340 2700 1000
  16 16.9 260 250 340 1100 1000
  24 20.2 365 300 400 2200 1000